Is a 13.5 kWh Home Battery Too Big? Measured Daily Solar Surplus and Night Use in 103 LA Homes

For a typical Los Angeles solar home, a 13.5 kWh battery is more than the daily routine needs. Across 103 homes without a battery, the panels sent a median 16 kWh a day to the grid and the home bought back 13 kWh at other hours. The energy a battery could actually move from one to the other — the smaller of the two each day — was a median 8.5 kWh. A 13.5 kWh battery would have filled and emptied completely on only 18% of days, and been about 61% used on an average day; a 10 kWh battery about 75%. Bigger households and backup for outages are the cases where more storage earns its keep.

Updated October 15, 2026 · Data through October 2026 · Cali Energy research team · CSLB #1032379 · verify license

8.5 kWh
Energy a day a battery could shift, median home without a battery
61%
Average daily use of a 13.5 kWh battery at that home
18%
Days a 13.5 kWh battery would fill and empty completely
82%
Daily charge of real batteries, share of capacity (18 that cycle)

A battery earns its keep by storing solar the house would otherwise export and using it later instead of grid power. How much it can do in a day is capped by both sides: the surplus available to charge it and the evening and night use available to discharge into.

About 8–9 kWh a day to shiftThe median home had 8.5 kWh a day that a battery could move from midday to evening; the middle half of homes 5–12 kWh.
13.5 kWh is rarely filledOnly on 18% of days would the median home have filled and used a 13.5 kWh battery completely.
Summer needs moreJuly had 10.8 kWh a day to shift, December 6.7.
Real batteries rarely top outBatteries in our fleet that cycle took in a median 82% of capacity a day and reached 90% or more on 27% of days.

A day’s surplus and a night’s need

103 homes without a battery, every clean day from January 2023 to mid-October 2026.

Daily energy flows, median home and middle half of homes
MeasureMedian homeMiddle half of homesTop tenth of homes
Home use a day25.9 kWh15–36 kWh51 kWh or more
Sent to the grid a day (surplus)15.9 kWh9–24 kWh29 kWh or more
Bought from the grid a day (need)13.2 kWh9–20 kWh31 kWh or more
Could be shifted by a battery (smaller of the two)8.5 kWh5–12 kWh17 kWh or more
Shiftable on a big day (each home’s 90th-percentile day)16.5 kWh9–23 kWh31 kWh or more
Each home’s median day, then the median across homes. A median day is lower than the yearly average: the same kind of homes used an average 31 kWh a day over a year, see home electricity use. “Shiftable” ignores battery losses of 10–20% and the order of the hours, so it is an upper bound for what a battery could do.
How to cite: Cali Energy, “Is a 13.5 kWh Home Battery Too Big?,” updated October 15, 2026, https://cali-energy.com/research/home-battery-size-daily-solar-surplus-los-angeles. Aggregated data are free to use under CC BY 4.0 with a link to this page.

How much of each battery size a home would use

Battery size against measured daily surplus and need, median home
Battery sizeDays it would fill and empty completelyMiddle half of homesAverage share used each dayMiddle half of homes
5 kWh79%48–91%91%79–96%
10 kWh36%6–65%75%51–87%
13.5 kWh18%1–42%61%38–78%
20 kWh3%0–18%43%26–61%
Average share used = mean over days of min(shiftable energy, battery size) ÷ battery size.

For the median home, a 5 kWh battery would be put to near-full use (91%) and a 10 kWh battery would still be about 75% used; a 13.5 kWh battery 61%, and a 20 kWh battery under half. That does not make a bigger battery wrong. The top quarter of homes would use a 13.5 kWh battery 78% or more of its capacity, an EV or heat pump can change the picture overnight, and a battery for outages is sized to the loads it must carry for a day or two, not to the daily surplus. What it should not be is sized by default.

Month by month

Median home, energy a day.

Energy a battery could shift each day, by month
Median homeMiddle half of homes
Shiftable energy per day by monthFrom 6.7 kWh in December to 10.8 in July.05101520JanFebMarAprMayJunJulAugSepOctNovDec
Bars: median home. Whiskers: middle half of homes.
Daily surplus, need and shiftable energy by month, median home
MonthSent to the gridBought from the gridCould be shifted
January11.0 kWh13.6 kWh7.7 kWh
February14.9 kWh12.0 kWh7.6 kWh
March19.6 kWh10.4 kWh7.7 kWh
April23.6 kWh8.7 kWh7.4 kWh
May22.0 kWh9.8 kWh6.9 kWh
June21.9 kWh12.4 kWh8.8 kWh
July17.6 kWh17.4 kWh10.8 kWh
August14.4 kWh20.7 kWh10.2 kWh
September14.6 kWh16.4 kWh9.7 kWh
October15.0 kWh12.1 kWh8.7 kWh
November11.4 kWh12.2 kWh7.5 kWh
December9.5 kWh14.5 kWh6.7 kWh

The need peaks in summer, when air conditioning runs into the evening: the median home bought 20.7 kWh a day from the grid in August and could have shifted 10.8 kWh a day in July. In spring there is plenty of surplus but little evening use to fill, and in winter the surplus itself runs short: 9.5 kWh a day sent to the grid in December. A battery sized for August sits partly idle in May and December.

How full real batteries get

18 batteries in our fleet that cycle 100 or more times a year, 2023–2026.

Daily charge of batteries that cycle, as a share of capacity
MeasureMedian batteryMiddle half
Charged per day, share of capacity82%58–89%
Days charged to 90% or more27%8–40%
Winter day (November–January)79%48–88%
Summer day (May–August)86%66–92%
Most of these batteries hold 10.08 or 20.16 kWh. Charge includes the energy a battery draws to stay ready.

The batteries already installed in our fleet, most of them 10 or 20 kWh, tell a similar story. On a typical day the median one took in 82% of its capacity, and it reached 90% or more on 27% of days. How many cycles that adds up to, and what it means for the warranty, is measured in how many cycles a year a home battery really does; what a battery changes in a home’s energy flows is in how much solar a home actually uses. To size your own: the battery sizing calculator.

Methodology

Homes
103 Enphase-monitored homes with a consumption meter and no battery, at least 300 clean days from January 2023 to mid-October 2026, with the data checks of the self-consumption study.
Shiftable energy
For each day, the smaller of the energy sent to the grid and the energy bought from it: the most a battery of unlimited size could have moved that day, ignoring losses and the order of the hours.
Battery sizes
For a size X, the share of days with shiftable energy of X or more, and the average of min(shiftable, X) ÷ X.
Real batteries
18 Enphase batteries with at least 300 clean days since 2023 and 100 or more cycles a year; daily charge ÷ usable capacity.
Limits
Rates, outage backup and future loads such as an EV are not modeled.

Frequently asked questions

Is a 13.5 kWh battery too big for my home?

For a typical LA solar home it is more than the daily routine fills: in our data it would be used about 61% on an average day and fill completely on 18% of days. Larger households, EVs and backup needs can justify it.

How much solar surplus is there to store each day?

The median home sent 16 kWh a day to the grid, but bought 13 kWh at other hours; the energy a battery could actually shift was about 8.5 kWh a day.

What battery size do most LA solar homes need for daily use?

Around 10 kWh covers most days for the median home (about 75% used on average); the middle half of homes could shift 5–12 kWh a day.

Do home batteries fill up every day?

No. Batteries in our fleet that cycle charged to a median 82% of capacity a day and reached 90% or more on 27% of days.

When does a battery help most?

In summer: the median home could shift 10.8 kWh a day in July, against 6.7 in December.

More research

Next steps

Sizing a battery for your home?

Prepared by Cali Energy, October 15, 2026. Figures describe systems in our monitoring fleet and are not a guarantee of what any specific roof will produce; orientation, tilt, shade, equipment and weather change results. Not engineering, financial or utility advice. See our Content Disclaimer.